“No Compromise Communications”
SG-2020 Transceiver
Test/Calibration Procedure
SG-2020 TEST DOCUMENT
This SG-2020 Test Document is divided into two sections:
Section One: Basic & Simple Test
Section Two: Full Test & Calibration
This test document is provided to SGC dealers, techni-
cians and engineers who have full knowledge and experi-
ence with electronics and HF radio communications. The
tests and calibration described must be performed using
appropriate, calibrated, good quality instruments.
Note that Section Two is not covered under the Warranty
of the SG-2020. Any information concerning this docu-
ment must be executed in writing only. These procedures
are provided as informational only to assist qualified tech-
nicians or engineers with field use and service of the SG-
2020 transceiver.
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - SG-2020 Transceiver

“No Compromise Communications”SG-2020 TransceiverTest/Calibration ProcedureSG-2020 TEST DOCUMENTThis SG-2020 Test Document is divided into two section

Page 2

12.0 RECEIVER SENSITIVITY TESTRMS level12.1 Set radio to 1800.0 KHz, RF max., AF max.12.2 Set audio distortion analyzer function to voltage reading,

Page 3

© 2001 SGC IncSGC Inc. SGC Building, 13737 S.E. 26th St. Bellevue, WA. 98005 USAP.O.Box 3526, 98009 Fax: 425-746-6384 or 746-7173 Tel: 425- 746-63

Page 4 - SGC TEST DESCRIPTION

SGC Inc. SGC Building, 13737 S.E. 26th St. Bellevue, WA. 98005 USAP.O.Box 3526, 98009 Fax: 425-746-6384 or 746-7173 Tel: 425- 746-6310 or 1-800-25

Page 5 - © 2001 SGC Inc

SG-2020 BASIC PERFORMANCE TESTSThe SGC factory test procedures as well as the test procedures detailed in theARRL Handbook chapter 26 can be used to f

Page 6

4. SWR Shutdown:Transmit 20 watts in CW mode with no antenna connected. You should getless than 5 LED’s on for forward power and full scale reading

Page 7

SGC TEST DESCRIPTIONNOTE: Any adjustments made to the SG-2020, besides the R46 CW sidetoneadjustment are NOT covered by the warranty.The following ar

Page 8

3.0 LPA BIASThis is not a routine procedure and should be done only when the finaltransistors are replaced.3.1 Set display for 14150.0 KHz, USB.3.2 C

Page 9

5.8 Continue on through step ARef. Point Step Adj. Tuning Knob for:VCXO ADJ. USB LO TP5 1 61,656.269 KHzLSB 2 61,666.294 KHzCW 3 61,663.157 KHz 5.8.1

Page 10 - © 2001 SGC Inc

5.16 Set all 20 default channels to factory preset frequencies. See page 20 of th SG-2020 Operations manual, Version 2.01.6.0 TRANSMIT SSB BALANCE (U

Page 11

Reverse Power7.6 Depress ‘REV’ while transmitting 20W into a dummy load and verifythat 2 LED’s light. 7.7 Depress ‘REV’ while transmitting 20 W witho

Page 12 - Selection